Updating docs to reflect iDRAC requirements

Signed-off-by: cgoveas <cassandra.goveas@dell.com>
cgoveas 3 năm trước cách đây
mục cha
commit
c5d780ce98

+ 2 - 1
docs/INSTALL_OMNIA_CONTROL_PLANE.md

@@ -230,7 +230,8 @@ Omnia performs the following configurations on AWX:
 * The device credentials are stored in **idrac_credential**, **ethernet_credential**, **infiniband_credential**, and **powervault_me4_credential**. The **node_credential** stores the credentials of nodes in the cluster. 
 * Four groups are created under **node_inventory**-manager, compute, login, and nfs. All nodes in the inventory are to be added to these groups from the AWX UI by the user.
 * iDRAC, networking switches, InfiniBand switches, and PowerVault storage devices can be configured using the respective templates: **idrac_template**, **ethernet_template**, **infiniband_template**, and **powervault_me4_template**. **deploy_omnia_template** is used to deploy Kubernetes and Slurm on the compute nodes. 
-* Schedules are created for the **node_inventory_job** (every **10 minutes**) and the **device_inventory_job** (**once daily**) to dynamically retrieve and update node and device details to AWX.  
+* Schedules are created for the **node_inventory_job** (every **60 minutes**) and the **device_inventory_job** (**once daily**) to dynamically retrieve and update node and device details to AWX. These jobs can also be run manually (node_inventory_job, device_inventory_job) if required.
+
 
 >> **Note**: The AWX configurations are automatically performed by Omnia, and Dell Technologies recommends that you do not change the default configurations that are provided by Omnia as the functionality may be impacted.  
 

Những thai đổi đã bị hủy bỏ vì nó quá lớn
+ 1 - 1
docs/control_plane/device_templates/CONFIGURE_INFINIBAND_SWITCHES.md


+ 1 - 0
docs/control_plane/device_templates/PROVISION_SERVERS.md

@@ -43,6 +43,7 @@ For the `idrac.yml` file to successfully provision the custom ISO on the PowerEd
 * The Redfish services are enabled in the iDRAC settings under **Services**.
 * The PowerEdge Servers have the iDRAC Enterprise or Datacenter license. If the license is not found, servers will be PXE booted and provisioned using Cobbler.  
 * If `provision_method` is set to PXE in `base_vars.yml`, ensure that all PXE devices have a configured, active NIC. To verify/ configure NIC availability: On the server, go to `BIOS Setup -> Network Settings -> PXE Device`. For each listed device (typically 4), configure/ check for an active NIC under `PXE device settings`
+* iDRAC 9 based Dell EMC PowerEdge Servers with firmware versions 5.00.10.20 and above. (With the latest BIOS available)
 
 The **provision_idrac** file configures and validates the following:
 * Required input parameters and prerequisites.