# Dell EMC PowerVault Storage
## Update the input parameters
Under the `control_plane/input_params` directory, edit the following files:
1. `base_vars.yml` file: Update the following variable to enable or disable PowerVault Storage configurations in the cluster.
Variable | Default, choices | Description
------- | ---------------- | -----------------
powervault_support |
| Set the variable to "true" to enable PowerVault Storage configurations.
2. `login_vars.yml` file: Enter the following details to configure PowerVault Storage devices.
a. `powervault_me4_username`- username for PowerVault Storage devices.
**NOTE**: The username must not contain the following characters: -, \\, "", and \'
b. `powervault_me4_password`- password for PowerVault Storage devices.
**NOTE**: Minimum length of the password must be eight characters and the maximum limit is 30 characters. The password must contain at least one uppercase, lowercase, numeric, and non-alphanumeric character. Do not use these characters while entering a password: -, \., \,, \<, \\, "", and \'
3. `powervault_me4_vars` file: If **powervault_support** is set to "true" in the *base_vars.yml* file, then update the following variables.
Variables | Default, choices | Description
---------------- | ----------------- | -----------------
locale | | Represents the selected language. In Omnia 1.1, only English is supported.
powervault_me4_system_name [Optional] | - **Uninitialized_Name**
- User-defined name
| The system name used to identify the PowerVault Storage device. The name should be less than 30 characters and must not contain spaces.
powervault_me4_snmp_notify_level [Required] | - **none**
- crit
- error
- warn
- resolved
- info
| Select the SNMP notification levels for PowerVault Storage devices.
powervault_me4_raid_levels [Required] | - **raid1**
Examples:- r5/raid5: 3-16
- r6/raid6: 4-16
- r10/raid10: 4-16
- adapt: 12-128
| Enter the required RAID levels and the minimum and maximum number of disks for each RAID levels.
powervault_me4_disk_range [Required] | | Enter the range of disks in the format *enclosure-number.disk-range,enclosure-number.disk-range*. For example, to select disks 3 to 12 in enclosure 1 and to select disks 5 to 23 in enclosure 2, you must enter `1.3-12, 2.5-23`. A RAID 10 or 50 disk group with disks in subgroups are separated by colons (with no spaces). RAID-10 example:1.1-2:1.3-4:1.7,1.10 **NOTE**: Ensure that the entered disk location is empty and the **Usage** column lists the range as **AVAIL**. The disk range specified must be of the same vendor and they must have the same description.
powervault_me4_k8s_volume_name [Required] | - **k8s_volume**
- User-defined name
| Enter the Kubernetes volume name.
powervault_me4_slurm_volume_name [Required] | - **slurm_volume**
- User-defined name
| Enter the Slurm volume name.
powervault_me4_disk_group_name | - **omnia**
- User-defined name
| Enter the group name of the disk.
powervault_me4_disk_partition_size [Required] | - **5**
- Any value between 5-90
| Enter the partition size which would be used as an NFS share.
powervault_me4_volume_size [Required] | | Enter the volume size in the format: *SizeTB*, *SizeGB*, *SizeMB*, or *SizeB*.
powervault_me4_pool [Required] | | Enter the pool for the volume.
powervault_me4_pool_type [Required] | | Select the type of pool to be deployed on PowerVault. Ensure that all pools on the device are exclusively virtual or linear.
## Deploy Omnia Control Plane
Before you configure the PowerVault Storage devices, you must complete the deployment of Omnia control plane. Go to Step 8 in the [Steps to install the Omnia Control Plane](../../INSTALL_OMNIA_CONTROL_PLANE.md#steps-to-deploy-the-omnia-control-plane) file to run the `ansible-playbook control_plane.yml` file.